Harald Quick

Prof. Harald H. Quick, PhD

Director



Room: OG 0.17
Phone: +49 201 183-6071
Email: harald.quick@uni-due.de
VCard:

Publications (179)

  • Law I, NL Albert, J Arbizu, R Boellaard, A Drzezga, N Galldiks, Cl Fougère, K Langen, E Lopci, V Lowe, J McConathy, HH Quick, B Sattler, DM Schuster, J Tonn, M Weller, Joint EANM/EANO/RANO practice guidelines/SNMMI procedure standards for imaging of gliomas using PET with radiolabelled amino acids and [18F]FDG: version 1.0., European journal of nuclear medicine and molecular imaging (2018)
  • Oehmigen M, ME Lindemann, M Gratz, R Neji, A Hammers, M Sauer, T Lanz, HH Quick, A dual-tuned 13 C/1 H head coil for PET/MR hybrid neuroimaging: Development, attenuation correction, and first evaluation., Medical physics (2018)
  • Grimm A, H Meyer, MD Nickel, M Nittka, E Raithel, O Chaudry, A Friedberger, M Uder, W Kemmler, K Engelke, HH Quick, Repeatability of Dixon magnetic resonance imaging and magnetic resonance spectroscopy for quantitative muscle fat assessments in the thigh., Journal of cachexia, sarcopenia and muscle (2018)
  • Kirchner J, J Grueneisen, O Martin, M Oehmigen, HH Quick, A Bittner, O Hoffmann, M Ingenwerth, OA Catalano, P Heusch, C Buchbender, M Forsting, G Antoch, K Herrmann, L Umutlu, Local and whole-body staging in patients with primary breast cancer: a comparison of one-step to two-step staging utilizing 18F-FDG-PET/MRI., European journal of nuclear medicine and molecular imaging (2018)
  • Grimm A, H Meyer, MD Nickel, M Nittka, E Raithel, O Chaudry, A Friedberger, M Uder, W Kemmler, HH Quick, K Engelke, Evaluation of 2-point, 3-point, and 6-point Dixon magnetic resonance imaging with flexible echo timing for muscle fat quantification., European journal of radiology (2018)
  • Suntharalingam S, E Mladenov, T Sarabhai, A Wetter, O Kraff, HH Quick, M Forsting, G Iliakis, K Nassenstein, Abdominopelvic 1.5-T and 3.0-T MR Imaging in Healthy Volunteers: Relationship to Formation of DNA Double-Strand Breaks., Radiology (2018)
  • Catana C, HH Quick, H Zaidi, Current commercial techniques for MRI-guided attenuation correction are insufficient and will limit the wider acceptance of PET/MRI technology in the clinic., Medical physics (2018)
  • Rietsch SHG, S Orzada, S Maderwald, S Brunheim, BWJ Philips, TWJ Scheenen, ME Ladd, HH Quick, 7T ultra-high field body MR imaging with an 8-channel transmit/32-channel receive radiofrequency coil array., Medical physics (2018)
  • Pfaffenrot V, S Brunheim, SHG Rietsch, PJ Koopmans, TM Ernst, O Kraff, S Orzada, HH Quick, An 8/15-channel Tx/Rx head neck RF coil combination with region-specific B1+ shimming for whole-brain MRI focused on the cerebellum at 7T., Magnetic resonance in medicine (2018)
  • Goebel J, F Nensa, HP Schemuth, S Maderwald, T Schlosser, S Orzada, S Rietsch, HH Quick, K Nassenstein, Feasibility of aortic valve planimetry at 7 T ultrahigh field MRI: Comparison to aortic valve MRI at 3 T and 1.5 T., European journal of radiology open (2018)
  • Lindemann ME, V Stebner, A Tschischka, J Kirchner, L Umutlu, HH Quick, Towards fast whole-body PET/MR: Investigation of PET image quality versus reduced PET acquisition times., PloS one (2018)
  • Quick HH, PET/MR hybrid imaging., Zeitschrift fur medizinische Physik (2017)
  • Kording F, C Ruprecht, B Schoennagel, K Fehrs, J Yamamura, G Adam, J Goebel, K Nassenstein, S Maderwald, HH Quick, O Kraff, Doppler ultrasound triggering for cardiac MRI at 7T., Magnetic resonance in medicine (2017)
  • Tran L, BM Huening, O Kaiser, B Schweiger, S Sirin, HH Quick, U Felderhoff-Mueser, D Timmann, Cerebellar-dependent associative learning is impaired in very preterm born children and young adults., Scientific reports (2017)
  • Deuschl C, J Kirchner, TD Poeppel, B Schaarschmidt, S Kebir, NE Hindy, J Hense, HH Quick, M Glas, K Herrmann, L Umutlu, C Moenninghoff, A Radbruch, M Forsting, M Schlamann, 11C-MET PET/MRI for detection of recurrent glioma., European journal of nuclear medicine and molecular imaging (2017)
  • Wierts R, W Jentzen, HH Quick, HJ Wisselink, INA Pooters, JE Wildberger, K Herrmann, GJ Kemerink, WH Backes, FM Mottaghy, Quantitative performance evaluation of <sup>124</sup>I PET/MRI lesion dosimetry in differentiated thyroid cancer., Physics in medicine and biology (2017)
  • Oehmigen M, ME Lindemann, M Gratz, J Kirchner, V Ruhlmann, L Umutlu, JO Blumhagen, M Fenchel, HH Quick, Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR., European journal of nuclear medicine and molecular imaging (2017)
  • Rietsch SHG, V Pfaffenrot, AK Bitz, S Orzada, S Brunheim, A Lazik-Palm, JM Theysohn, ME Ladd, HH Quick, O Kraff, An 8-channel transceiver 7-channel receive RF coil setup for high SNR ultrahigh-field MRI of the shoulder at 7T., Medical physics (2017)
  • Brunheim S, M Gratz, S Johst, AK Bitz, TM Fiedler, ME Ladd, HH Quick, S Orzada, Fast and accurate multi-channel B1+ mapping based on the TIAMO technique for 7T UHF body MRI., Magnetic resonance in medicine (2017)
  • Sawicki LM, S Lütje, X Baraliakos, J Braun, J Kirchner, J Boos, P Heusch, V Ruhlmann, K Herrmann, L Umutlu, HH Quick, G Antoch, C Buchbender, Dual-phase hybrid (18) F-Fluoride Positron emission tomography/MRI in ankylosing spondylitis: Investigating the link between MRI bone changes, regional hyperaemia and increased osteoblastic activity., Journal of medical imaging and radiation oncology (2017)
  • Lindemann ME, M Oehmigen, JO Blumhagen, M Gratz, HH Quick, MR-based truncation and attenuation correction in integrated PET/MR hybrid imaging using HUGE with continuous table motion., Medical physics (2017)
  • Brunheim S, S Johst, V Pfaffenrot, S Maderwald, HH Quick, BA Poser, Variable slice thickness (VAST) EPI for the reduction of susceptibility artifacts in whole-brain GE-EPI at 7 Tesla., Magma (New York, N.Y.) (2017)
  • Kraff O, HH Quick, 7T: Physics, safety, and potential clinical applications., Journal of magnetic resonance imaging : JMRI (2017)
  • Rietsch SHG, S Orzada, AK Bitz, M Gratz, ME Ladd, HH Quick, Parallel transmit capability of various RF transmit elements and arrays at 7T MRI., Magnetic resonance in medicine (2017)
  • Rausch I, HH Quick, J Cal-Gonzalez, B Sattler, R Boellaard, T Beyer, Technical and instrumentational foundations of PET/MRI., European journal of radiology (2017)
  • Sommer T, W Bauer, K Fischbach, C Kolb, R Luechinger, U Wiegand, J Lotz, I Eitel, M Gutberlet, H Thiele, HH Schild, M Kelm, HH Quick, J Schulz-Menger, J Barkhausen, D Bänsch, MR Imaging in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators., RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin (2017)
  • Deuschl C, C Moenninghoff, S Goericke, J Kirchner, S Köppen, I Binse, TD Poeppel, HH Quick, M Forsting, L Umutlu, K Herrmann, J Hense, M Schlamann, Response assessment of bevacizumab therapy in GBM with integrated 11C-MET-PET/MRI: a feasibility study., European journal of nuclear medicine and molecular imaging (2017)
  • Noureddine Y, O Kraff, ME Ladd, KH Wrede, B Chen, HH Quick, G Schaefers, AK Bitz, In vitro and in silico assessment of RF-induced heating around intracranial aneurysm clips at 7 Tesla., Magnetic resonance in medicine (2017)
  • Gramsch C, I Reuter, O Kraff, HH Quick, C Tanislav, F Roessler, C Deuschl, M Forsting, M Schlamann, Nigrosome 1 visibility at susceptibility weighted 7T MRI-A dependable diagnostic marker for Parkinson's disease or merely an inconsistent, age-dependent imaging finding?, PloS one (2017)
  • Laader A, K Beiderwellen, O Kraff, S Maderwald, K Wrede, ME Ladd, TC Lauenstein, M Forsting, HH Quick, K Nassenstein, L Umutlu, 1.5 versus 3 versus 7 Tesla in abdominal MRI: A comparative study., PloS one (2017)
  • Orzada S, A Bitz, S Johst, M Gratz, M Völker, O Kraff, A Abuelhaija, T Fiedler, K Solbach, H Quick, M Ladd, Analysis of an integrated 8-Channel Tx/Rx body array for use as a body coil in 7-Tesla MRI, Frontiers in Physics (2017)
  • Lazik-Palm A, O Kraff, C Geis, S Johst, J Goebel, ME Ladd, HH Quick, JM Theysohn, Morphological imaging and T2 and T2* mapping of hip cartilage at 7 Tesla MRI under the influence of intravenous gadolinium., European radiology (2016)
  • Paulus DH, HH Quick, Hybrid Positron Emission Tomography/Magnetic Resonance Imaging: Challenges, Methods, and State of the Art of Hardware Component Attenuation Correction., Investigative radiology (2016)
  • Matsushige T, B Chen, P Dammann, S Johst, HH Quick, ME Ladd, M Forsting, U Sure, KH Wrede, Microanatomy of the subcallosal artery: an in-vivo 7 T magnetic resonance angiography study., European radiology (2016)
  • Lazik-Palm A, O Kraff, S Johst, HH Quick, ME Ladd, C Geis, K Körsmeier, S Landgraeber, JM Theysohn, Morphological and Quantitative 7 T MRI of Hip Cartilage Transplants in Comparison to 3 T-Initial Experiences., Investigative radiology (2016)
  • Goebel J, F Nensa, HP Schemuth, S Maderwald, M Gratz, HH Quick, T Schlosser, K Nassenstein, Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function., Journal of magnetic resonance imaging : JMRI (2016)
  • Oehmigen M, ME Lindemann, T Lanz, S Kinner, HH Quick, Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil., Medical physics (2016)
  • Hahnemann ML, O Kraff, S Maderwald, S Johst, S Orzada, L Umutlu, ME Ladd, HH Quick, TC Lauenstein, Non-enhanced magnetic resonance imaging of the small bowel at 7 Tesla in comparison to 1.5 Tesla: First steps towards clinical application., Magnetic resonance imaging (2016)
  • Chen B, T Schoemberg, O Kraff, P Dammann, AK Bitz, M Schlamann, HH Quick, ME Ladd, U Sure, KH Wrede, Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study., Magma (New York, N.Y.) (2016)
  • Voelker MN, O Kraff, D Brenner, A Wollrab, O Weinberger, MC Berger, S Robinson, W Bogner, C Wiggins, R Trampel, T Stöcker, T Niendorf, HH Quick, DG Norris, ME Ladd, O Speck, The traveling heads: multicenter brain imaging at 7 Tesla., Magma (New York, N.Y.) (2016)
  • Kraff O, A Lazik-Palm, R Heule, JM Theysohn, O Bieri, HH Quick, 7 Tesla quantitative hip MRI: a comparison between TESS and CPMG for T2 mapping., Magma (New York, N.Y.) (2016)
  • Gratz M, M Schlamann, S Goericke, S Maderwald, HH Quick, Evaluation of fast highly undersampled contrast-enhanced MR angiography (sparse CE-MRA) in intracranial applications - initial study., European radiology (2016)
  • Lazik A, JM Theysohn, C Geis, S Johst, ME Ladd, HH Quick, O Kraff, 7 Tesla quantitative hip MRI: T1, T2 and T2* mapping of hip cartilage in healthy volunteers., European radiology (2016)
  • Paulus DH, M Oehmigen, J Grüneisen, L Umutlu, HH Quick, Whole-body hybrid imaging concept for the integration of PET/MR into radiation therapy treatment planning., Physics in medicine and biology (2016)
  • Dammann P, K Wrede, Y Zhu, T Matsushige, S Maderwald, L Umutlu, HH Quick, U Hehr, M Rath, ME Ladd, U Felbor, U Sure, Correlation of the venous angioarchitecture of multiple cerebral cavernous malformations with familial or sporadic disease: a susceptibility-weighted imaging study with 7-Tesla MRI., Journal of neurosurgery (2016)
  • Matsushige T, B Chen, A Ringelstein, L Umutlu, M Forsting, HH Quick, U Sure, KH Wrede, Giant Intracranial Aneurysms at 7T MRI., AJNR. American journal of neuroradiology (2016)
  • Ruhlmann V, P Heusch, H Kühl, K Beiderwellen, G Antoch, M Forsting, A Bockisch, C Buchbender, HH Quick, Potential influence of Gadolinium contrast on image segmentation in MR-based attenuation correction with Dixon sequences in whole-body 18F-FDG PET/MR., Magnetic Resonance Materials in Physics, Biology and Medicine (2016)
  • Goebel J, F Nensa, B Bomas, HP Schemuth, S Maderwald, M Gratz, HH Quick, T Schlosser, K Nassenstein, Real-time SPARSE-SENSE cardiac cine MR imaging: optimization of image reconstruction and sequence validation., European radiology (2016)
  • Wrede KH, T Matsushige, SL Goericke, B Chen, L Umutlu, HH Quick, ME Ladd, S Johst, M Forsting, U Sure, M Schlamann, Non-enhanced magnetic resonance imaging of unruptured intracranial aneurysms at 7 Tesla: Comparison with digital subtraction angiography., European radiology (2016)
  • Beyer T, ML Lassen, R Boellaard, G Delso, M Yaqub, B Sattler, HH Quick, Investigating the state-of-the-art in whole-body MR-based attenuation correction: an intra-individual, inter-system, inventory study on three clinical PET/MR systems., Magma (New York, N.Y.) (2016)
  • Aklan B, M Oehmigen, K Beiderwellen, M Ruhlmann, DH Paulus, BW Jakoby, P Ritt, HH Quick, Impact of Point-Spread Function Modeling on PET Image Quality in Integrated PET/MR Hybrid Imaging., Journal of nuclear medicine : official publication, Society of Nuclear Medicine (2016)
  • Goebel J, F Nensa, HP Schemuth, S Maderwald, HH Quick, T Schlosser, K Nassenstein, Real-time SPARSE-SENSE cine MR imaging in atrial fibrillation: a feasibility study., Acta radiologica (Stockholm, Sweden : 1987) (2016)
  • Deuschl C, F Nensa, J Grueneisen, TD Poeppel, LM Sawicki, P Heusch, C Gramsch, C Mönninghoff, HH Quick, M Forsting, L Umutlu, M Schlamann, Diagnostic impact of integrated 18F-FDG PET/MRI in cerebral staging of patients with non-small cell lung cancer., Acta radiologica (Stockholm, Sweden : 1987) (2016)
  • Goebel J, I Seifert, F Nensa, HP Schemuth, S Maderwald, HH Quick, T Schlosser, C Jensen, O Bruder, K Nassenstein, Can Native T1 Mapping Differentiate between Healthy and Diffuse Diseased Myocardium in Clinical Routine Cardiac MR Imaging?, PloS one (2016)
  • Grueneisen J, LM Sawicki, BM Schaarschmidt, S Suntharalingam, Svd Ropp, A Wetter, V Ruhlmann, HH Quick, M Forsting, L Umutlu, Evaluation of a Fast Protocol for Staging Lymphoma Patients with Integrated PET/MRI., PloS one (2016)
  • Deuschl C, S Goericke, J Grueneisen, LM Sawicki, J Goebel, NE Hindy, K Wrede, I Binse, T Poeppel, H Quick, M Forsting, J Hense, L Umutlu, M Schlamann, Simultaneous 11C-Methionine Positron Emission Tomography/Magnetic Resonance Imaging of Suspected Primary Brain Tumors., PloS one (2016)
  • Schelhorn J, C Gramsch, C Deuschl, HH Quick, F Nensa, C Moenninghoff, M Schlamann, Intracranial hemorrhage detection over time using susceptibility-weighted magnetic resonance imaging., Acta radiologica (Stockholm, Sweden : 1987) (2015)
  • Stalder AF, M Schmidt, HH Quick, M Schlamann, S Maderwald, P Schmitt, Q Wang, MS Nadar, MO Zenge, Highly undersampled contrast-enhanced MRA with iterative reconstruction: Integration in a clinical setting., Magnetic resonance in medicine (2015)
  • Ziegler S, BW Jakoby, H Braun, DH Paulus, HH Quick, NEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging., EJNMMI physics (2015)
  • Bailey DL, BJ Pichler, B Gückel, H Barthel, AJ Beer, J Bremerich, J Czernin, A Drzezga, C Franzius, V Goh, M Hartenbach, H Iida, A Kjaer, Cl Fougère, CN Ladefoged, I Law, K Nikolaou, HH Quick, O Sabri, J Schäfer, Combined PET/MRI: Multi-modality Multi-parametric Imaging Is Here: Summary Report of the 4th International Workshop on PET/MR Imaging; February 23-27, 2015, Tübingen, Germany., Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging (2015)
  • Boellaard R, I Rausch, T Beyer, G Delso, M Yaqub, HH Quick, B Sattler, Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems., Medical physics (2015)
  • Sommer T, R Luechinger, J Barkhausen, M Gutberlet, HH Quick, K Fischbach, German Roentgen Society Statement on MR Imaging of Patients with Cardiac Pacemakers., RöFo : Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin (2015)
  • Kinner S, H Eggebrecht, S Maderwald, J Barkhausen, SC Ladd, HH Quick, P Hunold, FM Vogt, Dynamic MR angiography in acute aortic dissection., Journal of magnetic resonance imaging : JMRI (2015)
  • Hahnemann ML, O Kraff, S Orzada, L Umutlu, S Kinner, ME Ladd, HH Quick, TC Lauenstein, T1-Weighted Contrast-Enhanced Magnetic Resonance Imaging of the Small Bowel: Comparison Between 1.5 and 7 T., Investigative radiology (2015)
  • Grueneisen J, J Nagarajah, C Buchbender, O Hoffmann, BM Schaarschmidt, T Poeppel, M Forsting, HH Quick, L Umutlu, S Kinner, Positron Emission Tomography/Magnetic Resonance Imaging for Local Tumor Staging in Patients With Primary Breast Cancer: A Comparison With Positron Emission Tomography/Computed Tomography and Magnetic Resonance Imaging., Investigative radiology (2015)
  • Rietsch SHG, HH Quick, S Orzada, Impact of different meander sizes on the RF transmit performance and coupling of microstrip line elements at 7 T., Medical physics (2015)
  • Schaarschmidt B, C Buchbender, B Gomez, C Rubbert, F Hild, J Köhler, J Grueneisen, H Reis, V Ruhlmann, A Wetter, HH Quick, G Antoch, P Heusch, Thoracic staging of non-small-cell lung cancer using integrated (18)F-FDG PET/MR imaging: diagnostic value of different MR sequences., European journal of nuclear medicine and molecular imaging (2015)
  • Schaarschmidt BM, J Grueneisen, P Heusch, B Gomez, K Beiderwellen, V Ruhlmann, L Umutlu, HH Quick, G Antoch, C Buchbender, Oncological whole-body staging in integrated (18)F-FDG PET/MR: Value of different MR sequences for simultaneous PET and MR reading., European journal of radiology (2015)
  • Paulus DH, HH Quick, C Geppert, M Fenchel, Y Zhan, G Hermosillo, D Faul, F Boada, KP Friedman, T Koesters, Whole-Body PET/MR Imaging: Quantitative Evaluation of a Novel Model-Based MR Attenuation Correction Method Including Bone., Journal of nuclear medicine : official publication, Society of Nuclear Medicine (2015)
  • Bailey DL, G Antoch, P Bartenstein, H Barthel, AJ Beer, S Bisdas, DA Bluemke, R Boellaard, CD Claussen, C Franzius, M Hacker, H Hricak, Cl Fougère, B Gückel, SG Nekolla, BJ Pichler, S Purz, HH Quick, O Sabri, B Sattler, Combined PET/MR: The Real Work Has Just Started. Summary Report of the Third International Workshop on PET/MR Imaging; February 17-21, 2014, Tübingen, Germany., Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging (2015)
  • Aklan B, BW Jakoby, CC Watson, H Braun, P Ritt, HH Quick, GATE Monte Carlo simulations for variations of an integrated PET/MR hybrid imaging system based on the Biograph mMR model., Physics in medicine and biology (2015)
  • Boellaard R, HH Quick, Current image acquisition options in PET/MR., Seminars in nuclear medicine (2015)
  • Gensler D, P Mörchel, F Fidler, O Ritter, HH Quick, ME Ladd, WR Bauer, G Ertl, PM Jakob, P Nordbeck, Myocardial T1: quantification by using an ECG-triggered radial single-shot inversion-recovery MR imaging sequence., Radiology (2015)
  • Johst S, S Maderwald, A Fischer, HH Quick, ME Ladd, S Orzada, Investigation of the saturation pulse artifact in non-enhanced MR angiography of the lower extremity arteries at 7 Tesla., PloS one (2015)
  • Moenninghoff C, O Kraff, S Maderwald, L Umutlu, JM Theysohn, A Ringelstein, KH Wrede, C Deuschl, J Altmeppen, ME Ladd, M Forsting, HH Quick, M Schlamann, Diffuse axonal injury at ultra-high field MRI., PloS one (2015)
  • Nordbeck P, HH Quick, W Bauer, G Ertl, ME Ladd, O Ritter, Initial clinical application of real-time MR imaging-guided ablation of cardiac arrhythmia in patients with atrial flutter., Radiology (2014)
  • Oehmigen M, S Ziegler, BW Jakoby, J Georgi, DH Paulus, HH Quick, Radiotracer dose reduction in integrated PET/MR: implications from national electrical manufacturers association phantom studies., Journal of nuclear medicine : official publication, Society of Nuclear Medicine (2014)
  • Paulus DH, D Thorwath, H Schmidt, HH Quick, Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning., Medical physics (2014)
  • Bailey DL, H Barthel, B Beuthin-Baumann, T Beyer, S Bisdas, R Boellaard, J Czernin, A Drzezga, U Ernemann, C Franzius, B Gückel, R Handgretinger, M Hartenbach, D Hellwig, H Nadel, SG Nekolla, T Pfluger, BJ Pichler, HH Quick, O Sabri, Combined PET/MR: Where are we now? Summary report of the second international workshop on PET/MR imaging April 8-12, 2013, Tubingen, Germany., Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging (2014)
  • Quick HH, Integrated PET/MR., Journal of magnetic resonance imaging : JMRI (2014)
  • Blumhagen JO, H Braun, R Ladebeck, M Fenchel, D Faul, K Scheffler, HH Quick, Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging., Medical physics (2014)
  • Braun H, S Ziegler, MG Lentschig, HH Quick, Implementation and performance evaluation of simultaneous PET/MR whole-body imaging with continuous table motion., Journal of nuclear medicine : official publication, Society of Nuclear Medicine (2014)
  • Attenberger UI, HH Quick, A Guimaraes, O Catalano, JN Morelli, SO Schoenberg, Value of new MR techniques in MR-PET., Der Radiologe (2013)
  • Paulus DH, L Tellmann, HH Quick, Towards improved hardware component attenuation correction in PET/MR hybrid imaging., Physics in medicine and biology (2013)
  • Bailey DL, H Barthel, T Beyer, R Boellaard, B Gückel, D Hellwig, H Herzog, BJ Pichler, HH Quick, O Sabri, K Scheffler, HP Schlemmer, NF Schwenzer, HF Wehrl, Summary report of the First International Workshop on PET/MR imaging, March 19-23, 2012, Tübingen, Germany., Molecular imaging and biology : MIB : the official publication of the Academy of Molecular Imaging (2013)
  • Vogt F, J Theysohn, D Michna, P Hunold, U Neudorf, S Kinner, J Barkhausen, HH Quick, Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA., European radiology (2013)
  • Ziegler S, H Braun, P Ritt, C Hocke, T Kuwert, HH Quick, Systematic evaluation of phantom fluids for simultaneous PET/MR hybrid imaging., Journal of nuclear medicine : official publication, Society of Nuclear Medicine (2013)
  • Kartmann R, DH Paulus, H Braun, B Aklan, S Ziegler, BK Navalpakkam, M Lentschig, HH Quick, Integrated PET/MR imaging: automatic attenuation correction of flexible RF coils., Medical physics (2013)
  • Nordbeck P, HH Quick, ME Ladd, O Ritter, Real-time MR guidance of interventional electrophysiology procedures with passive catheter visualization and tracking, Heart rhythm (2013)
  • Umutlu L, AK Bitz, S Maderwald, S Orzada, S Kinner, O Kraff, I Brote, SC Ladd, T Schroeder, M Forsting, G Antoch, ME Ladd, HH Quick, TC Lauenstein, Contrast-enhanced ultra-high-field liver MRI: a feasibility trial., European journal of radiology (2013)
  • Navalpakkam BK, H Braun, T Kuwert, HH Quick, Magnetic resonance-based attenuation correction for PET/MR hybrid imaging using continuous valued attenuation maps., Investigative radiology (2013)
  • Quick HH, Cv Gall, M Zeilinger, M Wiesmüller, H Braun, S Ziegler, T Kuwert, M Uder, A Dörfler, WA Kalender, M Lell, Integrated whole-body PET/MR hybrid imaging: clinical experience., Investigative radiology (2013)
  • Michaely HJ, HH Quick, State of the art hybrid MRI: advances in methodology and initial clinical results: focusing on MR-PET., Investigative radiology (2013)
  • Umutlu L, S Maderwald, S Kinner, O Kraff, AK Bitz, S Orzada, S Johst, K Wrede, M Forsting, ME Ladd, TC Lauenstein, HH Quick, First-pass contrast-enhanced renal MRA at 7 Tesla: initial results., European radiology (2013)
  • Aklan B, DH Paulus, E Wenkel, H Braun, BK Navalpakkam, S Ziegler, C Geppert, EE Sigmund, A Melsaether, HH Quick, Toward simultaneous PET/MR breast imaging: systematic evaluation and integration of a radiofrequency breast coil., Medical physics (2013)
  • Kinner S, HH Quick, S Maderwald, P Hunold, J Barkhausen, F Vogt, Triple-TWIST MRA: high spatial and temporal resolution MR angiography of the entire peripheral vascular system using a time-resolved 4D MRA technique, European radiology (2013)
  • Wiesmüller M, HH Quick, B Navalpakkam, MM Lell, M Uder, P Ritt, D Schmidt, M Beck, T Kuwert, CCv Gall, Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT., European journal of nuclear medicine and molecular imaging (2013)
  • Nordbeck P, F Fidler, M Friedrich, I Weiss, M Warmuth, D Gensler, V Herold, W Geistert, P Jakob, G Ertl, O Ritter, ME Ladd, W Bauer, HH Quick, Reducing RF-related heating of cardiac pacemaker leads in MRI: Implementation and experimental verification of practical design changes, Magnetic resonance in medicine (2012)
  • Umutlu L, S Maderwald, O Kraff, S Kinner, LC Schaefer, K Wrede, G Antoch, M Forsting, ME Ladd, TC Lauenstein, HH Quick, New look at renal vasculature: 7 tesla nonenhanced T1-weighted FLASH imaging., Journal of magnetic resonance imaging : JMRI (2012)
  • Nordbeck P, M Beer, H Köstler, ME Ladd, HH Quick, W Bauer, O Ritter, Cardiac catheter ablation under real-time magnetic resonance guidance, European heart journal (2012)
  • Paulus DH, H Braun, B Aklan, HH Quick, Simultaneous PET/MR imaging: MR-based attenuation correction of local radiofrequency surface coils., Medical physics (2012)
  • Braun H, S Ziegler, DH Paulus, HH Quick, Hybrid PET/MRI imaging with continuous table motion., Medical physics (2012)
  • Kahlert P, N Parohl, J Albert, L Schäfer, R Reinhardt, G Kaiser, I McDougall, B Decker, B Plicht, R Erbel, H Eggebrecht, ME Ladd, HH Quick, Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance (2012)
  • Reiter T, D Gensler, O Ritter, I Weiss, W Geistert, R Kaufmann, S Hoffmeister, M Friedrich, S Wintzheimer, M Duering, P Nordbeck, P Jakob, ME Ladd, HH Quick, W Bauer, Direct cooling of the catheter tip increases safety for CMR-guided electrophysiological procedures, Journal of cardiovascular magnetic resonance (2012)
  • Kahlert P, N Parohl, J Albert, L Schäfer, R Reinhardt, G Kaiser, I McDougall, B Decker, B Plicht, R Erbel, H Eggebrecht, ME Ladd, HH Quick, Real-time magnetic resonance imaging-guided transarterial aortic valve implantation in vivo evaluation in Swine, Journal of the American College of Cardiology (2012)
  • Gensler D, F Fidler, P Ehses, M Warmuth, T Reiter, M Düring, O Ritter, ME Ladd, HH Quick, P Jakob, W Bauer, P Nordbeck, MR safety: Fast T(1) thermometry of the RF-induced heating of medical devices, Magnetic resonance in medicine (2012)
  • Umutlu L, O Kraff, S Orzada, A Fischer, S Kinner, S Maderwald, G Antoch, HH Quick, M Forsting, ME Ladd, TC Lauenstein, Dynamic contrast-enhanced renal MRI at 7 Tesla: preliminary results., Investigative radiology (2011)
  • Nordbeck P, K Hiller, F Fidler, M Warmuth, N Burkard, M Nahrendorf, P Jakob, HH Quick, G Ertl, W Bauer, O Ritter, Feasibility of contrast-enhanced and nonenhanced MRI for intraprocedural and postprocedural lesion visualization in interventional electrophysiology: animal studies and early delineation of isthmus ablation lesions in patients with typical atrial flutter., Circulation. Cardiovascular imaging (2011)
  • Tellmann L, HH Quick, A Bockisch, H Herzog, T Beyer, The effect of MR surface coils on PET quantification in whole-body PET/MR: results from a pseudo-PET/MR phantom study., Medical physics (2011)
  • Umutlu L, S Orzada, S Kinner, S Maderwald, I Brote, AK Bitz, O Kraff, SC Ladd, G Antoch, ME Ladd, HH Quick, TC Lauenstein, Renal imaging at 7 Tesla: preliminary results., European radiology (2011)
  • Kraff O, AK Bitz, T Breyer, S Kruszona, S Maderwald, I Brote, E Gizewski, ME Ladd, HH Quick, A Transmit/Receive Radiofrequency Array for Imaging the Carotid Arteries at 7 Tesla: Coil Design and First In Vivo Results, Investigative radiology (2011)
  • Kalender W, HH Quick, Recent advances in medical physics., European radiology (2011)
  • Kinner S, M Zenge, C Heilmaier, Ad Greiff, F Vogt, ME Ladd, J Barkhausen, HH Quick, Peripheral MRA with k-space segmentation and blood-pool contrast agent, Academic radiology (2011)
  • Quick HH, Interventional MRI in the cardiovascular system., Methods in molecular biology (Clifton, N.J.) (2011)
  • Kraff O, AK Bitz, P Dammann, SC Ladd, ME Ladd, HH Quick, An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T., Medical physics (2010)
  • Seng K, S Maderwald, Ad Greiff, HH Quick, G Laub, P Schmitt, J Barkhausen, F Vogt, Dynamic contrast-enhanced magnetic resonance angiography of the thoracic vessels: an intraindividual comparison of different k-space acquisition strategies, Investigative radiology (2010)
  • Kahlert P, H Eggebrecht, B Plicht, O Kraff, I McDougall, B Decker, R Erbel, ME Ladd, HH Quick, Towards real-time cardiovascular magnetic resonance-guided transarterial aortic valve implantation: in vitro evaluation and modification of existing devices, Journal of cardiovascular magnetic resonance (2010)
  • Orzada S, S Maderwald, BA Poser, AK Bitz, HH Quick, ME Ladd, RF excitation using time interleaved acquisition of modes (TIAMO) to address B1 inhomogeneity in high-field MRI., Magnetic resonance in medicine (2010)
  • Umutlu L, S Maderwald, O Kraff, JM Theysohn, S Kuemmel, EA Hauth, M Forsting, G Antoch, ME Ladd, HH Quick, TC Lauenstein, Dynamic contrast-enhanced breast MRI at 7 Tesla utilizing a single-loop coil: a feasibility trial., Academic radiology (2010)
  • Nordbeck P, O Ritter, I Weiss, M Warmuth, D Gensler, N Burkard, V Herold, P Jakob, G Ertl, ME Ladd, HH Quick, W Bauer, Impact of imaging landmark on the risk of MRI-related heating near implanted medical devices like cardiac pacemaker leads, Magnetic resonance in medicine (2010)
  • Orzada S, S Maderwald, SL Göricke, N Parohl, SC Ladd, ME Ladd, HH Quick, Design and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system., Medical physics (2010)
  • Kos S, R Huegli, E Hofmann, HH Quick, H Kuehl, S Aker, G Kaiser, P Borm, A Jacob, D Bilecen, MR-compatible polyetheretherketone-based guide wire assisting MR-guided stenting of iliac and supraaortic arteries in swine: feasibility study., Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy (2010)
  • Mönninghoff C, S Maderwald, J Theysohn, O Kraff, S Ladd, ME Ladd, M Forsting, HH Quick, I Wanke, Evaluation of intracranial aneurysms with 7 T versus 1.5 T time-of-flight MR angiography - initial experience, RöFo : Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin (2009)
  • Kraff O, AK Bitz, S Kruszona, S Orzada, LC Schaefer, JM Theysohn, S Maderwald, ME Ladd, HH Quick, An eight-channel phased array RF coil for spine MR imaging at 7 T., Investigative radiology (2009)
  • Mekle R, M Zenge, ME Ladd, HH Quick, E Hofmann, K Scheffler, D Bilecen, Initial in vivo studies with a polymer-based MR-compatible guide wire, Journal of vascular and interventional radiology (2009)
  • Kos S, R Huegli, E Hofmann, HH Quick, H Kuehl, S Aker, G Kaiser, P Borm, A Jacob, D Bilecen, First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept., Cardiovascular and interventional radiology (2009)
  • Zenge M, ME Ladd, HH Quick, Novel reconstruction method for three-dimensional axial continuously moving table whole-body magnetic resonance imaging featuring autocalibrated parallel imaging GRAPPA, Magnetic resonance in medicine (2009)
  • Kos S, R Huegli, E Hofmann, HH Quick, H Kuehl, S Aker, G Kaiser, P Borm, A Jacob, D Bilecen, Feasibility of real-time magnetic resonance-guided angioplasty and stenting of renal arteries in vitro and in Swine, using a new polyetheretherketone-based magnetic resonance-compatible guidewire., Investigative radiology (2009)
  • Moser E, A Stadlbauer, C Windischberger, HH Quick, ME Ladd, Magnetic resonance imaging methodology, European journal of nuclear medicine and molecular imaging (2009)
  • Nordbeck P, I Weiss, P Ehses, O Ritter, M Warmuth, F Fidler, V Herold, P Jakob, ME Ladd, HH Quick, W Bauer, Measuring RF-induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leads, Magnetic resonance in medicine (2009)
  • Kramer H, HH Quick, B Tombach, S Schoenberg, J Barkhausen, Whole-Body MRA., European radiology (2008)
  • Beyer T, M Weigert, HH Quick, U Pietrzyk, F Vogt, C Palm, G Antoch, SP Müller, A Bockisch, MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data., European journal of nuclear medicine and molecular imaging (2008)
  • Maderwald S, S Ladd, E Gizewski, O Kraff, J Theysohn, K Wicklow, C Moenninghoff, I Wanke, ME Ladd, HH Quick, To TOF or not to TOF: strategies for non-contrast-enhanced intracranial MRA at 7 T, Magma (New York, N.Y.) (2008)
  • Brauck K, M Zenge, F Vogt, HH Quick, F Stock, T Trarbach, ME Ladd, J Barkhausen, Feasibility of whole-body MR with T2- and T1-weighted real-time steady-state free precession sequences during continuous table movement to depict metastases, Radiology (2008)
  • Nordbeck P, F Fidler, I Weiss, M Warmuth, M Friedrich, P Ehses, W Geistert, O Ritter, P Jakob, ME Ladd, HH Quick, W Bauer, Spatial distribution of RF-induced E-fields and implant heating in MRI, Magnetic resonance in medicine (2008)
  • Bieri O, S Patil, HH Quick, K Scheffler, Morphing steady-state free precession., Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine (2007)
  • Vogt F, M Zenge, ME Ladd, C Herborn, K Brauck, W Luboldt, J Barkhausen, HH Quick, Peripheral vascular disease: comparison of continuous MR angiography and conventional MR angiography–pilot study, Radiology (2007)
  • Kaiser G, F Breuckmann, S Aker, H Eggebrecht, H Kuehl, R Erbel, N Fruhauf, C Broelsch, HH Quick, Anesthesia for cardiovascular interventions and magnetic resonance imaging in pigs., Journal of the American Association for Laboratory Animal Science : JAALAS (2007)
  • Eggebrecht H, G Heusch, R Erbel, ME Ladd, HH Quick, Real-time vascular interventional magnetic resonance imaging: the future of aortic stent-graft placement?, Basic research in cardiology (2006)
  • Breuckmann F, K Nassenstein, D Boese, D Opherk, HH Quick, J Barkhausen, R Erbel, Successful nitinol stent implantation in a large coronary aneurysm: post-interventional patency assessment by magnetic resonance imaging., The international journal of cardiovascular imaging (2006)
  • Eggebrecht H, H Kühl, G Kaiser, S Aker, M Zenge, F Stock, F Breuckmann, F Grabellus, ME Ladd, R Mehta, R Erbel, HH Quick, Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection, European heart journal (2006)
  • Eggebrecht H, M Zenge, ME Ladd, R Erbel, HH Quick, In vitro evaluation of current thoracic aortic stent-grafts for real-time MR-guided placement, Journal of endovascular therapy (2006)
  • Zenge M, F Vogt, K Brauck, M Jökel, J Barkhausen, S Kannengiesser, ME Ladd, HH Quick, High-resolution continuously acquired peripheral MR angiography featuring partial parallel imaging GRAPPA, Magnetic resonance in medicine (2006)
  • Geckeis K, H Eggebrecht, HH Quick, J Barkhausen, A Kribben, R Erbel, A word of caution on the use of high-dose MR contrast media in patients with renal failure., Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists (2005)
  • Quick HH, M Zenge, H Kuehl, G Kaiser, S Aker, S Massing, S Bosk, ME Ladd, Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization, Magnetic resonance in medicine (2005)
  • Eggebrecht H, HH Quick, J Barkhausen, A Kribben, R Erbel, Re: high-dose intravenous gadolinium for renal computed tomographic angiography., Journal of vascular and interventional radiology : JVIR (2005)
  • Zenge M, ME Ladd, F Vogt, K Brauck, J Barkhausen, HH Quick, Whole-body magnetic resonance imaging featuring moving table continuous data acquisition with high-precision position feedback, Magnetic resonance in medicine (2005)
  • Vogt F, W Ajaj, P Hunold, C Herborn, HH Quick, J Debatin, S Ruehm, Venous compression at high-spatial-resolution three-dimensional MR angiography of peripheral arteries., Radiology (2004)
  • Uffmann K, S Maderwald, W Ajaj, C Galban, S Mateiescu, HH Quick, ME Ladd, In vivo elasticity measurements of extremity skeletal muscle with MR elastography, NMR in biomedicine (2004)
  • Herborn C, M Goyen, HH Quick, S Bosk, S Massing, K Kroeger, D Stoesser, S Ruehm, J Debatin, Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease., AJR. American journal of roentgenology (2004)
  • Quick HH, F Vogt, S Maderwald, C Herborn, S Bosk, S Göhde, J Debatin, ME Ladd, High spatial resolution whole-body MR angiography featuring parallel imaging: initial experience, RöFo : Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin (2004)
  • Quick HH, H Kuehl, G Kaiser, S Aker, S Bosk, J Debatin, ME Ladd, Interventional MR angiography with a floating table, Radiology (2003)
  • Quick HH, ME Ladd, Interventional MRA: concepts for active visualization of catheters and stents, Zeitschrift für medizinische Physik (2003)
  • Liffers A, HH Quick, C Herborn, H Ermert, ME Ladd, Geometrical optimization of a phased array coil for high-resolution MR imaging of the carotid arteries, Magnetic resonance in medicine (2003)
  • Quick HH, H Kuehl, G Kaiser, D Hornscheidt, K Mikolajczyk, S Aker, J Debatin, ME Ladd, Interventional MRA using actively visualized catheters, TrueFISP, and real-time image fusion, Magnetic resonance in medicine (2003)
  • Quick HH, H Kuehl, G Kaiser, S Bosk, J Debatin, ME Ladd, Inductively coupled stent antennas in MRI, Magnetic resonance in medicine (2002)
  • Goyen M, HH Quick, J Debatin, ME Ladd, J Barkhausen, C Herborn, S Bosk, H Kuehl, M Schlepütz, S Ruehm, Whole-body three-dimensional MR angiography with a rolling table platform: initial clinical experience, Radiology (2002)
  • Quick HH, ME Ladd, M Hoevel, S Bosk, J Debatin, G Laub, T Schroeder, Real-time MRI of joint movement with trueFISP, Journal of magnetic resonance imaging (2002)
  • Quick HH, J Debatin, ME Ladd, MR imaging of the vessel wall, European radiology (2002)
  • Barkhausen J, HH Quick, T Lauenstein, M Goyen, S Ruehm, G Laub, J Debatin, ME Ladd, Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study, Radiology (2001)
  • Quick HH, J Serfaty, H Pannu, R Genadry, C Yeung, E Atalar, Endourethral MRI., Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine (2001)
  • Ladd ME, HH Quick, J Debatin, Interventional MRA and intravascular imaging, Journal of magnetic resonance imaging (2000)
  • Serfaty J, X Yang, P Aksit, HH Quick, M Solaiyappan, E Atalar, Toward MRI-guided coronary catheterization: visualization of guiding catheters, guidewires, and anatomy in real time., Journal of magnetic resonance imaging : JMRI (2000)
  • Serfaty J, E Atalar, J Declerck, P Karmakar, HH Quick, K Shunk, A Heldman, X Yang, Real-time projection MR angiography: feasibility study., Radiology (2000)
  • Ruehm S, M Goyen, HH Quick, M Schlepütz, H Schlepütz, S Bosk, J Barkhausen, ME Ladd, J Debatin, Whole-body MRA on a rolling table platform (AngioSURF), RöFo : Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin (2000)
  • Nanz D, D Weishaupt, HH Quick, J Debatin, TE-switched double-contrast enhanced visualization of vascular system and instruments for MR-guided interventions., Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine (2000)
  • Ladd ME, HH Quick, Reduction of resonant RF heating in intravascular catheters using coaxial chokes, Magnetic resonance in medicine (2000)
  • Weishaupt D, HH Quick, D Nanz, M Schmidt, P Cassina, J Debatin, Ligating clips for three-dimensional MR angiography at 1.5 T: in vitro evaluation., Radiology (2000)
  • Hilfiker P, HH Quick, T Pfammatter, M Schmidt, J Debatin, Three-dimensional MR angiography of a nitinol-based abdominal aortic stent graft: assessment of heating and imaging characteristics., European radiology (2000)
  • Eyrich GK, E Bruder, P Hilfiker, B Dubno, HH Quick, MA Patak, KW Grätz, HF Sailer, Temperature mapping of magnetic resonance-guided laser interstitial thermal therapy (LITT) in lymphangiomas of the head and neck., Lasers in surgery and medicine (2000)
  • Quick HH, ME Ladd, D Nanz, K Mikolajczyk, J Debatin, Vascular stents as RF antennas for intravascular MR guidance and imaging, Magnetic resonance in medicine (1999)
  • Hilfiker P, HH Quick, M Schmidt, J Debatin, In vitro image characteristics of an abdominal aortic stent graft: CTA versus 3D MRA., Magma (New York, N.Y.) (1999)
  • Quick HH, ME Ladd, G Zimmermann-Paul, P Erhart, E Hofmann, Gv Schulthess, J Debatin, Single-loop coil concepts for intravascular magnetic resonance imaging, Magnetic resonance in medicine (1999)
  • Hilfiker P, HH Quick, J Debatin, Plain and covered stent-grafts: in vitro evaluation of characteristics at three-dimensional MR angiography., Radiology (1999)
  • Quick HH, ME Ladd, P Hilfiker, G Paul, S Ha, J Debatin, Autoperfused balloon catheter for intravascular MR imaging, Journal of magnetic resonance imaging (1999)
  • Zimmermann-Paul G, HH Quick, P Vogt, Gv Schulthess, D Kling, J Debatin, High-resolution intravascular magnetic resonance imaging: monitoring of plaque formation in heritable hyperlipidemic rabbits., Circulation (1999)
  • Zimmermann-Paul G, ME Ladd, T Pfammatter, P Hilfiker, HH Quick, J Debatin, MR versus fluoroscopic guidance of a catheter/guidewire system: in vitro comparison of steerability, Journal of magnetic resonance imaging (1998)
  • Ladd ME, G Zimmermann, HH Quick, J Debatin, P Boesiger, Gv Schulthess, G McKinnon, Active MR visualization of a vascular guidewire in vivo, Journal of magnetic resonance imaging (1998)
  • Zimmermann G, HH Quick, P Hilfiker, Kv Schulthess, P Giovanoli, J Debatin, Intravascular MR imaging: the first in-vivo experiences in an animal arteriosclerosis model, RöFo : Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin (1997)
« Back to team page